中文字幕无码一本到无线,日韩免费一区二区三区,国产成人精品日本亚洲语音,亚洲午夜一级在线观看,色播亚洲精品无码网站,中文字幕在线看片

產(chǎn)品搜索:
產(chǎn)品資料
產(chǎn)品[

DPG1000ADA-15G-3N壓力表 美國(guó)omega

]資料
如果您對(duì)該產(chǎn)品感興趣的話,可以 sendmsg
產(chǎn)品名稱(chēng): DPG1000ADA-15G-3N壓力表 美國(guó)omega
產(chǎn)品型號(hào): DPG1000ADA-15G-
產(chǎn)品廠商: 美國(guó)Omega熱電偶
產(chǎn)品文檔: 無(wú)相關(guān)文檔
簡(jiǎn)單介紹
    DPG1000ADA-15G-3N壓力表 美國(guó)omega由美國(guó)omega原廠渠道的深圳鑫博恒業(yè)科技有限公司特價(jià)提供,DPG1000ADA-15G-3N壓力表 美國(guó)omega精度高,壽命長(zhǎng),DPG1000ADA-15G-3N壓力表 美國(guó)omega是值得信賴(lài)的傳感器。
DPG1000ADA-15G-3N壓力表 美國(guó)omega 的詳細(xì)介紹

DPG1000ADA-15G-3N壓力表 美國(guó)omega

報(bào)警裝置和模擬輸出功能的數(shù)字壓力計(jì)
DPG1000ADA_DPG1000DAR系列
DPG1000ADA_DPG1000DAR 系列:報(bào)警裝置和模擬輸出功能的數(shù)字壓力計(jì)
DPG1000ADA-15G-1N
AD or DC Powered with Dual Alarms
DC Powered with Dual Alarms and Analog Output
Ranges between 15 psi and 3000 psi
Normal or Reverse Acting Alarms
Hi/Lo, Hi/Hi, or Lo/Lo Alarms available
Colored LED Alarm Status Indicators
Using the DPG1000ADA and DPG1000DAR Alarm Outputs Normal (Fail-safe) vs. Reverse Action—The convention for alarm action is that with the normal or fail-safe configuration, the alarm output relays will be CLOSED (relay energized) for a clear or non-alarm condition and OPEN (relay not energized) for an alarm condition. This is primarily for users who require an alarm condition if the gauge loses power or suffers a catastrophic failure. In the wiring diagrams, the normally closed and normally open designations refer to standard relay terminology (i.e., the relay contact status with the relay coil not energized). Therefore, with the normal (fail-safe) configuration in a green or non-alarm condition, the relay will be energized so that continuity can be expected between the common and normally open leads. In a red or alarm condition, the relay will be open (not energized) so that continuity can be expected between the common and normally closed leads.
Contact Rating and Protection The contacts of the alarm relays are rated at 1 A/24 Vdc or 0.5 A/ 115 Vac. Switching loads greater than the rating, or switching large inductive loads, will shorten the useful life of the contacts. In lowlevel switching or with dry contacts, the user should consider whether external contact protection, such as snubber networks or arc suppression networks, is required to protect the contacts. In addition, no internal fusing is included in the DPG1000 contact circuits. The circuit external to the gauge alarm outputs should be fused by the user in applications in which good design dictates this practice.
Using the DPG1000DAR Analog Output The analog output is easy to use if a few system considerations are observed. The DPG1000DAR is DC powered, with the gauge power supply (–) tied to the 4 to 20 mA (–). Therefore, the DC supply (–) lead should be considered common with regard to the analog output (–) or ground connection in the user’s system. Be sure to observe the output compliance (voltage drive) capabilities of the gauge. The compliance, and therefore the maximum loop resistance the output can drive, is a function of the supply voltage to the gauge. Consult the manual for maximum loop resistance vs. supply voltage. Too large a loop resistance will cause the gauge output to “limit” or saturate before reaching its full 20 mA output.
DPG1000ADA AC/DC Powered with Dual Alarms
SPECIFICATIONS
Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)
Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers
Alarm Deadbands (Hysteresis): 1% of FSO, standard
Alarm Outputs: Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive
Alarm Indicators: Bicolor (red/green) LEDs on front panel
Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation
Alarm Response Time: 100 ms typical
Power: Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS)
DPG1000DAR DC Powered with Dual Alarms and 4 to 20 mA Output
SPECIFICATIONS
Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)
Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; test calibration level, 0 to 100% range; top-accessible, multiturn potentiometers analog output zero/span; internal potentiometers
Alarm Deadbands (Hysteresis): 1% of FSO, standard
Alarm Outputs: Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive
Alarm Indicators: Bi-color (red/green) LEDs on front panel
Alarm Response Time: 100 ms typical
Analog Output: 4 to 20 mA DC; output drive (compliance) determined by power source
Analog Output Response Time: 50 ms, typical
Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status and simultaneously sets display and analog output to “calibration” level, independent of pressure input, to allow testing system operation
Power: Any DC source of 9 to 32 Vdc, 1.0 W max
Electrical Connection: 0.9 m (3') long, 4-conductor 22 AWG shielded cable for power and retransmitted output; 0.9 m (3') long, 6-conductor 22 AWG cable for alarm contacts
ALARMS (final siffix 1N standard)
1 = HI/LO (standard)
2= HI/HI
3= LO/LO
N = Normal Acting (standard)
R = Reverse Acting
Example: DPG1000ANA-15G-3R HAS LO/LO ALARMS, Reverse Acting

 DPG1000ADA-15G-3N壓力表 美國(guó)omega 

產(chǎn)品留言
標(biāo)題
聯(lián)系人
聯(lián)系電話
內(nèi)容
驗(yàn)證碼
點(diǎn)擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!


熱門(mén)產(chǎn)品
img15
推薦產(chǎn)品
img15
*新產(chǎn)品
img15
品牌目錄
img15
img15
img16
深圳市鑫博恒業(yè)科技有限公司 版權(quán)所有
電話:0755-82768776 82736276    傳真:0755-83041664  電郵 :info@xb5j.cn
地址:深圳市福田區(qū)華強(qiáng)北路華強(qiáng)廣場(chǎng)A棟17A(華強(qiáng)北地鐵站-A口)  郵編:518031
粵ICP備09037369號(hào)  

著作權(quán)聲明
  

粵公網(wǎng)安備 44030402001378號(hào)

连江县| 尉氏县| 古浪县| 武宣县| 邵阳县| 曲水县| 张家界市| 双辽市| 民勤县| 中超| 邹平县| 双城市| 泽库县| 昌平区| 凌云县| 古田县| 万安县| 金堂县| 溧水县| 永仁县| 濮阳县| 白山市| 共和县| 崇仁县| 大兴区| 枣阳市| 历史| 敦煌市| 曲靖市| 阜南县| 黔南| 若尔盖县| 怀来县| 南丰县| 桂平市| 嘉义县| 古蔺县| 广丰县| 荣昌县| 高邮市| 庐江县|